FEC DSP1500 (SAN3) User Manual

Page 113

Advertising
background image


enFORCE

DSP1500 SAN Unit Operation Manual

PAGE 6-37 (Rev

4)

Chapter 6: System Operation


¾

Data Number 60 - Slow Start Time

ƒ

Ramp up time value at start of cycle. [70: Slow Start Speed] is performed during Slow

Start Time.
A setting is possible from 0 to 999.9.

¾

Data Number 61 - Load Hold Time

ƒ

The press will hold the [14: Target Load] or [33: Target Distance] for the amount of

time set.

If 999.9 (1 figure below the decimal) or 9999 (no decimal point) is set, Load Hold Time is
set to no limitation. It finishes operating when the START signal goes OFF.
If using the “Advanced” signal, a time must be set. The “Advanced” signal will stay on for
this set time.
A setting is possible from 0 to 999.9.

The set time for “F-type” tools should generally be kept to 1 second or
less unless duty cycle calculations have been done and the tool is
oversized for the application. If it is set and operated over 1 second,
abnormal 8-10 (overload abnormal) may occur.

The press uses [74: Press Speed 2] to control the holding of the target
load or distance. Depending on the forces acting against the press ram, if
this speed is set too fast it may cause the holding operation to fluctuate
more than desired due to reaction timing and inertia. To avoid this keep
[74: Press Speed 2] set low.

¾

Data Number 62 - Press Time (Method 5)

ƒ

The amount of time the press will run after reaching [20: Time Start Load].

Operation will stop if this time is exceeded

A setting is possible from 0 to 327.6.

¾

Data Number 63 - Press Time Low Limit (Method 8)

¾

Data Number 64 - Press Time High Limit (Method 8)

ƒ

In [Distance Control with Load Limit] method, this is the min. and max. time limits.

A setting is possible from 0 to 999.9.





[35]

Approach Distance

[61]

Load Hold

Time

[70] Slow Start Speed

[37] Press Speed 1 Start

Distance

Or

[16] Press Speed 1 Start Load

[60]

Slow Start Time

[33]

Target

Distance

Or

[14] Load

[73] Press Speed 1

[72] Part Search

Speed

[71] Approach Speed

[75] Decompression

Speed

Time/
Distance

[74] Press Speed 2

[38]

Press Speed 2

Start Distance

Or

[17] Press Speed 2 Start Load

[76] Return Speed

Speed

Time Settings

Advertising