Channel code – Yokogawa Multi Channel Oxygen Analyzer System ZR22/AV550G User Manual

Page 36

Advertising
background image

IM 11M12D01-01E

2-17

2. Specifications

Model and Suffix Code

1. Detector
Refer to GS 11M12A01-01E for a detailed explanation of the detector specifications

and available accessories.

2. Averaging Converter

Model

AV550G

Base

(*1)

Number of Channel
Card (*2)

Display

Options

Power supply

Communication

Option

Code

Suffix Code

-A
-B

-A1
-A2
-A3
-A4
-A5
-A6
-A7
-A8
-B1
-B2
-B3
-B4
-B5
-B6
-B7
-B8

-J
-E
-F
-G

-1
-2

-E
-F

Stainless steel tag plate

24 Voltage output for Solenoid valve
Cable gland (Numbers in )

/SCT
/24
/G

Specification

Averaging Converter

4 Channel Base
8 Channel Base

1

Oxygen Channel Card, Common Isolation

2

Oxygen Channel Cards, Common Isolation

3

Oxygen Channel Cards, Common Isolation

4

Oxygen Channel Cards, Common Isolation

5

Oxygen Channel Cards, Common Isolation

6

Oxygen Channel Cards, Common Isolation

7

Oxygen Channel Cards, Common Isolation

8

Oxygen Channel Cards, Common Isolation

1

Oxygen Channel Card, Individual Isolation

2

Oxygen Channel Cards, Individual Isolation

3

Oxygen Channel Cards, Individual Isolation

4

Oxygen Channel Cards, Individual Isolation

5

Oxygen Channel Cards, Individual Isolation

6

Oxygen Channel Cards, Individual Isolation

7

Oxygen Channel Cards, Individual Isolation

8

Oxygen Channel Cards, Individual Isolation

Japanese
English
French
German

100 / 115 V AC
230 V AC

HART communication
FOUNDATION Fieldbus communication

T02.EPS

(*5)

(*3)

(*1)

Select code "-B" (8 Channel Base) when future expansion exceeding 4 channels is expected.

By so doing, the expansion can be made economically.

(*2)

Common isolation is recommended, when the same instrument receives the analog

outputs from each channel card. Individual isolation is recommended to prevent the
trouble by mutual interference, when different instrument receives the analog outputs
from each channel card.

(*5)

Input 01 to 30 in

ᮀ ᮀ

.

(*3)

When suffix code "-2" (230 V AC) is selected, select code "-A" (4 Channel Base).

(*4)

When suffix code "-F" (FOUNDATION Fieldbus communication) is selected, used exclusively

for communication.

(*4)

3. Channel Code

Option

/K2

(*2)

Expansion power supply unit for 24 volt
output of solenoid valve output.

(*3)

(*3) Expansion power supply unit is required, when using the 4 channel base and extending the number of
channel cards to five or more. Available only in U.S.

Model

AV55CM

Number of
Channels (*1)

Option

Code

Suffix Code

-A1
-A2
-A3
-A4
-A5
-A6
-A7
-A8
-B1
-B2
-B3
-B4
-B5
-B6
-B7
-B8

-A

/K1

Specification

Channel Card

1

Oxygen Channel Card, Common Isolation

2

Oxygen Channel Cards, Common Isolation

3

Oxygen Channel Cards, Common Isolation

4

Oxygen Channel Cards, Common Isolation

5

Oxygen Channel Cards, Common Isolation

6

Oxygen Channel Cards, Common Isolation

7

Oxygen Channel Cards, Common Isolation

8

Oxygen Channel Cards, Common Isolation

1

Oxygen Channel Card, Individual Isolation

2

Oxygen Channel Cards, Individual Isolation

3

Oxygen Channel Cards, Individual Isolation

4

Oxygen Channel Cards, Individual Isolation

5

Oxygen Channel Cards, Individual Isolation

6

Oxygen Channel Cards, Individual Isolation

7

Oxygen Channel Cards, Individual Isolation

8

Oxygen Channel Cards, Individual Isolation

Always -A

Expansion power supply unit for dry contact
output of solenoid valve output.

T03.EPS

(*1) -A

are common Isolation types -B

are Individual Isolation types

Up to 4 channel cards can be added in the 230 VAC version.

(*2) Expansion power supply unit is required, when using the 4 channel base and extending the number of
channel cards to five or more.
The expansion power supply unit cannot be added in the 230 VAC version.

Advertising