Yokogawa Single Channel Oxygen Analyzer System ZR22/ZR402 User Manual

Page 25

Advertising
background image

IM 11M13A01-02E

2-6

Model

ZR22S

Flange
(*2)

-A
-B
-C
-E
-F
-G
-K
-L
-M
-P
-Q
-R
-S
-W

Separate type Explosionproof Zirconia Oxygen Analyzer, Detector

Length

Wetted material

-A
-B
-C
-D

-S
-C

ATEX certified flameproof (*11)
FM certified explosionproof
CSA certified explosionproof
IECEx certified flameproof (*12)

SUS316
Stainless steel with Inconel calibration gas tube

(*7)

Suffix code

Option

code

Description

T2.1E.EPS

Reference air

-E

Gas Thread

-R
-T

Connection box thread

-M
-T

-A

-E

Options

-015
-040
-070
-100
-150
-200

0.15 m (for high temperature use) (*1)
0.4 m
0.7 m
1.0 m
1.5 m
2.0 m

Explosion
proof
Approval

Instruction manual

*1 Used with the ZO21P High Temperature Probe Adapter. Select flange (-Q).
*2 The thickness of the flange depends on its dimensions.
*3 The flange thickness does not conform to JIS specification.
*4 Inconel probe bolts and U shape pipe are used. Use this option for high temperature use (ranging from 600 to 700

ЊC).

*5 Specify either /CV or /SV option code. Please select /CV or /SV.

*6

Specify either /SCT or /PT option code.

*7 Recommended if measured gas contains corrosive gas like chlorine.
*8 Piping for reference air must be installed to supply reference air constantly at a specified flow rate.
*9 When selecting code -B (FM certified explosionproof) or -C (CSA certified explosionproof), select code -T (1/2 NPT).
*10 Confirm inside diameter of pipe attached to customer’s flange in case that -A or -E is selected.
*11 Certified cable glands that meet or exceed the requirements for EEx d IIB+H

2

IP66, provide at least 6 threads engaged when

installed, and resist heat so that they can be used in the operating environment, should be used.
*12 Certified cable glands that meet or exceed the requirements for Ex d IIB+H

2

T2, Ex tD A21 IP66 T300

ЊC

, provide at least

6 threads engaged when installed, and resist heat so that they can be used in the operating environment, should be used.

ANSI Class 150 2 RF SUS304 (*10)
ANSI Class 150 3 RF SUS304
ANSI Class 150 4 RF SUS304
DIN PN10 DN50 A SUS304 (*10)
DIN PN10 DN80 A SUS304
DIN PN10 DN100 A SUS304
JIS 5K 65 FF SUS304
JIS 10K 65 FF SUS304
JIS 10K 80 FF SUS304
JIS 10K 100 FF SUS304
JIS 5K 32 FF SUS304 (for high temperature use)

(*3)

JPI Class 150 4 RF SUS304
JPI Class 150 3 RF SUS304
Westinghouse

External connection (Instrument air)

(*8)

Rc 1/4
1/4 NPT

M20 x1.5 mm
1/2 NPT

(*9)

Always -A

English

Valves

Tag plates

Inconel bolt

(*4)

Check valve

(*5)

Stop valve

(*5)

Stainless steel tag plate

(*6)

Printed tag plate

(*6)

/C
/CV
/SV
/SCT
/PT