Yokogawa Single Channel Oxygen Analyzer System ZR22/ZR402 User Manual

Page 30

Advertising
background image

IM 11M12A01-03E

2-11

2. Specifications

Display and setting content:

Measuring-related items: Oxygen concentration (vol% O

2

), moisture quantity(vol% H

2

O),

mixture ratio (kg/kg), relative humidity (%RH) and dew point (

Њ C)

Display Related Items: Oxygen concentration (vol% O

2

), Moisture quantity (vol% H

2

O),

mixture ratio (kg/kg), relative humidity (%RH), dew point (

Њ C), cell tempera-

ture (

Њ C), thermocouple reference junction temperature (Њ C), maximum/

minimum/average oxygen concentration (vol% O

2

), maxi-mum/minimum/

average moisture quantity (vol% H

2

O), maximum/minimum/average mixture

ratio (kg/kg), cell e.m.f. (mV), output 1, 2 current (mA), cell response time
(seconds), cell internal resistance (

⍀), cell condition (in four grades), heater on-

time ratio (%), calibration history (ten times), time (year/month/day/hour/
minute)

Calibration Setting Items: Span gas concentration (vol% O

2

), zero gas concentration

(vol% O

2

), calibration mode (auto, semi-auto, manual), calibration type and

method (zero-span calibration, zero calibration only, span calibration only),
stabilization time (min.sec), calibration time (min.sec), calibration period (day/
hour), starting time (year/month/day/hour/minute)

Output Related Items: Analog output/output mode selection, value conditions when

warming-up/maintenance/calibrating(or blowback)/abnormal, oxygen concentra-
tion at 4mA/20mA (vol% O

2

), moisture quantity at 4mA/20mA (vol% H

2

O),

mixture ratio at 4mA/20mA (kg/kg), time constant.

Alarm Related Items: Oxygen concentration high-alarm/high-high alarm limit values

(vol% O

2

), Oxygen concentration low-alarm/low-low alarm limit values (vol%

O

2

), moisture quantity high-alarm/high-high alarm limit values (vol% H

2

O),

moisture quantity low-alarm/low-low alarm limit values (vol% H

2

O), mixture

ratio high-alarm/high-high alarm limit value (kg/kg), mixture ratio low-alarm/
low-low alarm limit values (kg/kg), oxygen concentration alarm hysteresis
(vol% O

2

), moisture quantity alarm hysteresis (vol% H

2

O), mixture ratio alarm

hysteresis (kg/kg), oxygen concentration/moisture quantity/mixture ratio alarm
detection, alarm delay (seconds).

Contact Related Items: Selection of contact input 1 and 2, selection of contact output 1

to 3 (abnormal, high-high alarm, high-alarm, low-alarm, low-low alarm,
maintenance, calibrating, range switching, warming-up, calibration-gas pres-
sure-decrease, temperature high-alarm, blow back, unburnt gas detected)

Converter Output: Two points mA analog output (4 to 20 mA DC (maximum load

resistance of 550

⍀) and one of two mA digital output points (HART) (mini-

mum load resistance of 250

⍀).

Range: any setting between 0 to 5 through 0 to 100 vol% O

2

, 0 to 25 through 0 to 100

vol% H

2

O, 0 to 0.200 through 0 to 1.000 kg/kg or partial range is available.

For the log output, the minimum range values are fixed at 0.1 vol% O

2

for the

oxygen concentration, 0.1 vol% H

2

O for the moisture quantity, and 0.01 kg/kg

for the mixture ratio.

4 to 20 mA DC linear or log can be selected.

Input/output isolation provided.

Output damping 0-255 (sec.)

Can select hold or non-hold, and set preset value for hold.