Displaying local meps, Figure 316 t – Brocade 6910 Ethernet Access Switch Configuration Guide (Supporting R2.2.0.0) User Manual

Page 1082

Advertising
background image

1026

Brocade 6910 Ethernet Access Switch Configuration Guide

53-1002651-02

43

Connectivity Fault Management

FIGURE 316

Transmitting Single-Ended Loss-Measure Messages

Displaying Local MEPs

Use the Administration > CFM > Show Information (Show Local MEP) page to show information for
the MEPs configured on this device.

CLI References

•

“show ethernet cfm maintenance-points local”

on page 532

•

“show ethernet cfm maintenance-points local detail mep”

on page 533

Parameters
These parameters are displayed:

•

MEP ID – Maintenance end point identifier.

•

MD Name – Maintenance domain name.

•

Level – Authorized maintenance level for this domain.

•

Direction – Direction in which the MEP communicates CFM messages:

•

Down indicates that the MEP is facing away from the switch, and transmits CFM messages
towards, and receives them from, the direction of the physical medium.

•

Up indicates that the MEP faces inward toward the switch cross-connect matrix, and
transmits CFM messages towards, and receives them from, the direction of the internal
bridge relay mechanism.

•

Primary VLAN – Service VLAN ID.

•

Interface – Physical interface of this entry (either a port or trunk).

•

CC Status – Shows administrative status of CCMs.

•

MAC Address – MAC address of this MEP entry.

Advertising