Resetting the system, Figure 27 – Brocade 6910 Ethernet Access Switch Configuration Guide (Supporting R2.2.0.0) User Manual

Page 753

Advertising
background image

Brocade 6910 Ethernet Access Switch Configuration Guide

697

53-1002651-02

33

Resetting the System

Parameters
The following parameters are displayed:

•

Free Size – The amount of memory currently free for use.

•

Used Size – The amount of memory allocated to active processes.

•

Total – The total amount of system memory.

Interface
To display memory utilization:

1. Click System, then Memory Status.

FIGURE 27

Displaying Memory Utilization

Resetting the System

Use the System > Reset menu to restart the switch immediately, at a specified time, after a
specified delay, or at a periodic interval.

CLI References

•

“reload (Privileged Exec)”

on page 44

•

“reload (Global Configuration)”

on page 40

•

“show reload”

on page 44

Command Usage

•

This command resets the entire system.

•

When the system is restarted, it will always run the Power-On Self-Test. It will also retain all
configuration information stored in non-volatile memory by the

copy running-config

startup-config

command (see

“copy”

on page 67).

Parameters
The following parameters are displayed:

System Reload Configuration

•

Reset Mode – Restarts the switch immediately or at the specified time(s).

•

Immediately – Restarts the system immediately.

•

In – Specifies an interval after which to reload the switch. (The specified time must be
equal to or less than 24 days.)

•

hours – The number of hours, combined with the minutes, before the switch resets.
(Range: 0-576)