ERPS Commands

Default Setting
0

Command Mode
ERPS Configuration

Command Usage

•

This parameter is used to ensure that received R-APS PDUs are directed for this ring. A unique
level should be configured for each local ring if there are many R-APS PDUs passing through
this switch.

•

If CFM continuity check messages are used to monitor the link status of an ERPS ring node as
specified by the

mep-monitor

command, then the MEG level set by the meg-level command

must match the authorized maintenance level of the CFM domain to which the specified MEP
belongs.

Example

Console(config-erps)#meg-level 0

Console(config-erps)#

Related Commands

“ethernet cfm domain”

on page 524

“ethernet cfm mep”

on page 528

mep-monitor

This command specifies the CFM MEPs used to monitor the link on a ring node. Use the no form to
restore the default setting.

Syntax

mep-monitor {east | west} mep mpid

east - Connects to next ring node to the east.

west - Connects to next ring node to the west.

mpid – Maintenance end point identifier. (Range: 1-8191)

Default Setting
None

Command Mode
ERPS Configuration

Command Usage

•

If this command is used to monitor the link status of an ERPS node with CFM continuity check
messages, then the MEG level set by the

meg-level

command must match the authorized

maintenance level of the CFM domain to which the specified MEP belongs.

•

To ensure complete monitoring of a ring node, use the mep-monitor command to specify the
CFM MEPs used to monitor both the east and west ports of the ring node.