Spanning Tree Commands

duration - The duration to shut down the interface.
(Range: 60-86400 seconds)

Default Setting
block

Command Mode
Interface Configuration (Ethernet, Port Channel)

Command Usage

•

If an interface is shut down by this command, and the release mode is set to “auto” with the

spanning-tree loopback-detection release-mode

command, the selected interface will be

automatically enabled when the shutdown interval has expired.

•

If an interface is shut down by this command, and the release mode is set to “manual,” the
interface can be re-enabled using the

spanning-tree loopback-detection release

command.

Example

Console(config)#interface ethernet 1/5

Console(config-if)#spanning-tree loopback-detection action shutdown 600

spanning-tree loopback-detection release-mode

This command configures the release mode for a port that was placed in the discarding state
because a loopback BPDU was received. Use the no form to restore the default.

Syntax

spanning-tree loopback-detection release-mode {auto | manual}

no spanning-tree loopback-detection release-mode

auto - Allows a port to automatically be released from the discarding state when the
loopback state ends.

manual - The port can only be released from the discarding state manually.

Default Setting
auto

Command Mode
Interface Configuration (Ethernet, Port Channel)

Command Usage

•

If the port is configured for automatic loopback release, then the port will only be returned to
the forwarding state if one of the following conditions is satisfied:

•

The port receives any other BPDU except for it’s own, or;

•

The port’s link status changes to link down and then link up again, or;

•

The port ceases to receive it’s own BPDUs in a forward delay interval.

•

If Port Loopback Detection is not enabled and a port receives it’s own BPDU, then the port will
drop the loopback BPDU according to IEEE Standard 802.1W-2001 9.3.4 (Note 1).

•

Port Loopback Detection will not be active if Spanning Tree is disabled on the switch.