6.18.6

Patrol

In the Main menu press the PATROL key to enter the graphics management page for this function.

START STANDARD PATROL
To start the corresponding function.
START S.A. PATROL
To start the corresponding function.
TOGGLE STANDARD PATROL
Inverts current status. If the function is in progress it
will be stopped and vice versa.
TOGGLE S.A. PATROL
Inverts current status. If the function is in progress it
will be stopped and vice versa.
STOP PATROL
To stop the (Standard or S.A.) PATROL function in
progress.

SETUP STANDARD PATROL
To enter the setup menu for the Standard PATROL function.

SETUP S.A. PATROL
To enter the setup menu for the S.A.. PATROL function.

The graphics page displayed by the keyboard is identical for all types of receiver and for both the
VIDEOTEC and Macro protocols. See the handbook for the individual receiver to verify which
functions are actually available for each protocol.

6.18.6.1

Setup Standard PATROL

The PATROL sequence comprises a series of Preset positions that are reached in succession with the same
dwell time for each position.
The Standard PATROL can have a maximum of 14 positions.
Changing the PATROL only becomes effective after completing transmission of the configuration to the
receiver.

Procedure for defining the Standard PATROL:

Position the cursor on the Preset position to be accepted and press the “

ent

” key.

To change the dwell time, position the cursor on the item “Dwell time” and press the “

ent

” key. Insert the

desired value and confirm with the “

ent

” key.

To send the setting, position the cursor on the item “Send configuration” and press the “

ent

” key.

Press the “

esc

” key to return to the PATROL page.