Videotec DCT User Manual

Page 28

Advertising
background image

4.2.3.2.2

Protocol – Baud rate

The possible combinations are as follows (where the Baud rate values shown in bold type are the default
settings):

Connector

Protocol

Baud rate

A/B

-------------------------

-------------------------

BOSCH

2400-9600-19200-38400

ELBEX

4800

EL.MO.

9600

ENEO

2400-4800-9600

ERNITEC

1200-2400-4800-9600-19200-38400

FASTRAX

2400-4800-9600-19200

JVC 675

9600

JVC 676

9600

KALATEL

2400-4800-9600

MACRO

1200-9600-19200-38400

MARK M.

9600

PANAS600

2400-4800-9600-19200

PANAS850

2400-4800-9600-19200

PELCO

2400-4800-9600-19200

SAMSUNG

4800-9600-19200-38400

SANYO SSP

2400-4800-9600-19200

SANYO HSSP

2400-4800-9600-19200

SANTEC

2400-4800-9600-19200

SENSORMAT.

4800

VCL

9600

VIDEOTEC

1200-9600

4.2.3.2.3

Logical address

The default setting for the “Logical address ” parameter is “NO”.
This configuration is necessary if you choose to send telemetry controls to the video matrix, using the physical
address of the dome.
EXAMPLE: in the case where the video signal of camera 1 (logical address 1), which has physical address 23
with respect to the network, has to be displayed by a matrix that needs the address 23 for its own purposes and
not the logical address for the video to operate correctly.
If the “Logical address” parameter is set to “YES”, you choose to send telemetry controls to the video matrix
by making use of the logical address of the dome, even if the dome has been set to a different physical address
in the network.

The logical address must be set to “NO” with the following products:

8/4 ENEO matrix, EKR series

16/4 ENEO matrix, EKR series

4/2 VIDEOTEC matrix, SM..A series

8/2 VIDEOTEC matrix, SM..A series

8/4 VIDEOTEC matrix, SM..A series

16/4 VIDEOTEC matrix, SM..A

On the other hand, the following products can be used indifferently with the logical address setting to “YES”
or “NO”:

32/8 ENEO matrix, EKR series

32/8 VIDEOTEC matrix, SM..A series

If “NO” has been selected, the matrix must be set up so that it disables decodification of the receivers, while if
YES” has been selected the matrix must be setup so that it enables decodification of the receivers.

Page 26 of 176

MNVADCT03_0716