Videotec DCT User Manual

Page 58

Advertising
background image

5.3.1

ENEO video matrixes

5.3.1.1

EKR-8/4, EKR-16/4, EKR-32/8 models

5.3.1.1.1

Connection and operational test

The standard communication cable is used (see § 3.3 - One keyboard per line: standard connection cable,
page 15
).
Set the DIP switch appropriately inside the matrix (all DIPs OFF: Macro protocol, baud rate 38400,
programming disabled).
On completing the connection it should be immediately possible to switch the input videos using the
video/telemetry controls.

5.3.1.1.2

Matrix setup

The matrix can be set up via the corresponding menu (see § 5.3.4.1 - Macro OSM, page 58).

5.3.1.2

VKR-16/4, VKR-32/8 models

5.3.1.2.1

Connection and operational test

The connection diagram is as follows:

DCT

RJjack

Interface IN

Interface OUT

Matrix

RS485A

white

A

RX

TX

--

--

--

TX

RX

RS485B

yellow

B

GND

GND

In the matrix, set the communication protocol for port 3 (RS232 PC) as follows:
baud rate: 9600, parity: none, protocol: PC, number of characters: 8.
On completing the connection it should be immediately possible to switch the input videos using the
video/telemetry controls.
Only VKR-KB1 or VKR-KB2 ENEO type keyboards can be used for matrix setup.

5.3.2

VIDEOTEC video matrixes

5.3.2.1

SM42A

, SM82A

, SM84A

, SM164A

models

5.3.2.1.1

Connection and operational test

The standard communication cable is used (see § 3.3 - One keyboard per line: standard connection cable,
page 15
). Set the DIP switch appropriately inside the matrix (all DIPs OFF: Macro protocol, baud rate 38400,
programming disabled).
On completing the connection it should be immediately possible to switch the input videos using the
video/telemetry controls.

5.3.2.1.2

Matrix setup

The matrix can be set up via the corresponding menu (see § 5.3.4.1 - Macro OSM, page 58).

Page 56 of 176

MNVADCT03_0716

Advertising