Code

Function

63

Start autoscan for alarm

64

Stop autoscan for alarm

OTHER

71

Heater on

72

Fan on

73

Audio muting: mute

74

Light: on

75

IR Filter: cut filter mode

81

Heater off

82

Fan off

83

Audio muting: normal

84

Light: off

85

IR Filter: focus filter mode

PRESET POSITIONS

1000

Add all Preset positions

10XX

XX = 01 ÷ 99: add one Preset position

1100

Remove all Preset positions

11XX

XX = 01 ÷ 99: remove one Preset position

12XX

XX = 01 ÷ 99: dwell time (in seconds) after reaching each position

1300

Movement at maximum speed

130X

X = 1 ÷ 8: reduced speed of movement

ALARM POSITIONS

2000

Add all alarm positions

20XX

XX = 01 ÷ 99: add one alarm position

2100

Remove all alarm positions

21XX

XX = 01 ÷ 99: remove one alarm position

22XX

XX = 01 ÷ 99: dwell time (in seconds) after reaching each position

2300

Movement at maximum speed

230X

X = 1 ÷ 8: reduced speed of movement

TIMER FUNCTIONS

40XX

XX = 00 ÷ 56: Stop autopan
00: continuous; 01 ÷ 23: from 5 to 115 minutes (step = 5 minutes); 24 ÷ 44: from 2 to 12
hours (step = 30 minutes); 45 ÷ 56: from 13 to 24 hours (step = 1 hour)

4XYY

Reset Aux contacts
X = 1 ÷ 8: contact number
YY = 00 ÷ 28: time:
00: continuous; 01 ÷ 05: from 1 to 5 minutes (step = 1 minute); 06 ÷ 15: from 10 to 55
minutes (step = 5 minutes); 16 ÷ 27: from 1 to 12 hours (step = 1 hour); 28: 24 hours

Page 82 of 176