6. Electrical installation

Festo P.BE-CMMD-AS-HW-EN 1002NH

105

6.4

Interfaces and plug assignments

6.4.1

I/O interface [X1.1/2]

Mode switching allows assignment of the [X1] interface more than once.
As a result, a maximum of four different I/O assignments can be selected. These are
described in the following tables:

- Table 6.2 Pin allocation: I/O interface [X1] mode 0
- Table 6.3 Pin allocation: I/O interface [X1] mode 1
- Table 6.4 Pin allocation: I/O interface [X1] mode 2
- Table 6.5 Pin allocation: I/O interface [X1] mode 3

Mode

DIN9

DIN12

Mode 0 – Positioning

0

0

Mode 1 – Jog mode

0

1

Mode 2 – Route program

1

0

Mode 3 – Synchronisation

1

1

Table 6.1 Mode switching

Pin

Designation

Value

Mode = 0 – Positioning

1

AGND

0 V

Screen for analogue signals

2

AIN0 / DIN12 ±10 V

Digital I/O control interface: DIN12 Mode selection (high active)
Analogue input control interface:
Setpoint input 0, differential, maximum 30 V input voltage

3

DIN10

Record selection 4 (high active)

4

+VREF

+10 V ±4 %

Reference output for setpoint potentiometer

5

free

6

GND24

Ass.GND

Reference potential for digital inputs and outputs

7

DIN1

Record selection 1 (high active)

8

DIN3

Record selection 3 (high active)

9

DIN5

Controller release EN (high active)

10

DIN7

Limit switch 1

11

DIN9

Digital I/O control interface: Mode selection (high active)
Fieldbus contorl interface:
Sample input (high-speed input)

12

DOUT1

24 V100 mA

Output freely programmable – default: Motion complete (high active)

13

DOUT3

24 V100 mA

Output freely programmable – default: Error (low active)

14

AGND

0 V

Reference potential for the analogue signals

15

#AIN0 /
DIN13

Ri = 20 k

Digital I/O control interface: Stop input (low active)
Analogue input control interface:
Reference potential setpoint input 0, differential

16

DIN11

Record selection 5 (high active)

17

AMON0

0 ... 10 V

Analogue monitor output 0

18

+ 24 V

24 V100 mA

24 V feed-in feed-out

19

DIN0

Record selection 0 (high active)

20

DIN2

Record selection 2 (high active)

21

DIN4

Output stage enable (high active)