Homing, 5 homing – Festo Контроллер двигателя CMMD-AS User Manual
Page 53
3. Product description
Festo P.BE-CMMD-AS-HW-EN 1002NH
53
3.7.5
Homing
You can choose either of the following methods which are based on DS402.
Run to
Positive
method
Negative
method
Graphical representation
Dec Hex Dec Hex
Limit switch with zero pulse
evaluation
2
02
1
01
Negativer
Endschalter
Index Impuls
1
Fixed stop with zero pulse
evaluation
–2
FE
–1
FF
Index Impuls
-1
Limit switch
18
12
17
11
Fixed stop
–18 EE
–17 EF
-
1
7
Zero pulse
34
22
33
21
Save current position
35
23
35
23
Table 3.15 Methods of homing
Method
1
Negative proximity switch with index pulse.
If negative limit switch inactive:
Run at search speed in negative direction to the negative limit switch.
Run at crawl speed in positive direction until the limit switch becomes inactive,
then on to first index pulse. This position is saved as a reference point.
If configured: Run at travel speed to axis zero point.