3. Product description

28

Festo P.BE-CMMD-AS-HW-EN 1002NH

3.5.2

Analogue setpoint specification

The analogue setpoint specification +/- 10V DC can be configured as

- speed setpoint value
- torque setpoint value.

Required activation with analogue setpoint specification

14533d_1

The connection plan shows the switch position in the active operating state.
*) The limit switches are set by default to opener (configuration over FCT)

3.5.3

Interfaces for direct synchronous operation

The motor controller permits a master-slave operation, which hereafter is designated
synchronisation. The controller can function either as a master or slave.
If the motor controller works as master, it can provide (RS422) A/B signals to the
increment generator output (X10).
When the motor controller is to operate as a slave, various inputs and signal forms are
available for synchronisation.

[X10] (5 V RS422) A/B, CW/CCW, CLK/DIR
[X1] (24 V)

CW/CCW, CLK/DIR)