3. Product description
28
Festo P.BE-CMMD-AS-HW-EN 1002NH
3.5.2
Analogue setpoint specification
The analogue setpoint specification +/- 10V DC can be configured as
- speed setpoint value
- torque setpoint value.
Required activation with analogue setpoint specification
14533d_1
The connection plan shows the switch position in the active operating state.
*) The limit switches are set by default to opener (configuration over FCT)
3.5.3
Interfaces for direct synchronous operation
The motor controller permits a master-slave operation, which hereafter is designated
synchronisation. The controller can function either as a master or slave.
If the motor controller works as master, it can provide (RS422) A/B signals to the
increment generator output (X10).
When the motor controller is to operate as a slave, various inputs and signal forms are
available for synchronisation.
[X10] (5 V RS422) A/B, CW/CCW, CLK/DIR
[X1] (24 V)
CW/CCW, CLK/DIR)