A. Technical data

130

Festo P.BE-CMMD-AS-HW-EN 1002NH

A.3.6

Power supply [X9]

Characteristics

Values

Supply voltage

Single-phase/ 95 ... 255 V AC
Suitable for USA/EU mains voltage

Frequency

50 … 60 Hz

Nominal input current

8 ... 10 A

Link voltage

320 V DC

Maximum intermediate circuit voltage

400 V DC with supply voltage 230 V AC

Control section supply voltage

24 V DC ±20

%

Control section nominal current

approx. 0.7 A DC

Nominal output current

2 x 4 A

Peak current

2 x 10 A for 2 s or 0.5 s with stopped motor

Intermediate circuit rated power

1200 W

Cooling

passive

End stage power loss

60 … 70 W

Own power loss control section

16 W

Table A.15 Technical data: Power data [X9]

Note

To release the holding brake, the voltage tolerances at the holding
brake connection terminals must be maintained.


Characteristics

Value internal

External values

Braking resistance

115

≤ 50

Pulse power

1400 W

3200 W

Rated output

30 W

200 W

Response threshold

380 ... 400 V

380 ... 400 V

Hysteresis

10 V

10 V

Table A.16 Technical data: Braking resistor [X9]

A.3.7

Increment generator interface [X10.1/2]

Increment generator interface

Values

Operating modes

A/B, CW/CCW or CLK/DIR input signals
A,B,N output signals

Angle resolution / number of lines

Any number of lines can be set (all whole numbers
between 16 and 2048)

Tracking signals

According to RS422 standard

Output impedance

120 Ω

Cut-off frequency at

f

Limit

> 500 kHz

Table A.17 Increment generator interface [X10]