3. Product description

Festo P.BE-CMMD-AS-HW-EN 1002NH

37

Parameter commands

The exchange of parameters and data takes place over "communication objects" (CO).
They are used in a fixed syntax. Special return values are defined for errors in a write or
read access.

Note

To address the communication objects (CO) of axis 2, the character
# is set before the syntax command.

Answers of axis 2 begin with the character #.

The same applies for simulated CAN accesses.

Examples

Acknowledge error axis 1

OW:0030:0001 0000 Answer: OK!

Acknowledge error axis 2 #OW 0030:0001 0000 Answer: #OK!


Homing mode axis 1 Command: =606000:06
Homing mode axis 2 Command: #=606000:06

Command

Syntax

Response

Reading a CO

OR:nnnn

nnnn:HHHHHHHH or OR:EEEEEEEE

Writing a CO

OW:nnnn:HHHHHHHH OK! or OW:EEEEEEEE

Reading a lower limit of a CO

ON:nnnn

nnnn:HHHHHHHH or ON:EEEEEEEE

Reading an upper limit of a CO

OX:nnnn

nnnn:HHHHHHHH or OX:EEEEEEEE

Reading an actual value of a CO

OI:nnnn

nnnn:HHHHHHHH or OI:EEEEEEEE

*)nnnn:

Number of the communication object (CO), 16 bit (hexadecimal format)

HHHHHHHH: 32 bit data / values (hexadecimal format)
EEEEEEEE:

Return value in case of an access fault

Table 3.8 Parameter commands

The meaning of the return values is the following:

Return value

Significance

0x0000 0002

Data are less than the lower limit, data were not written

0x0000 0003

Data are greater than the upper limit, data were not written

0x0000 0004

Data are less than the lower limit, the data were limited to the lower limit
and then accepted

0x0000 0005

Data are greater than the upper limit, the data were limited to the upper limit
and then accepted

0x0000 0008

Data are outside the valid value range and were not written

0x0000 0009

Data are currently outside the valid value range and were not written

Table 3.9 Return values