Festo P.BE-CMMD-AS-HW-EN 1002NH

71

Required I/O interface for record linking

14529d_1

The connection plan shows the switch position in the active operating state.
*) The limit switches are set by default to opener (configuration over FCT)

With removal of DIN3 "Halt record linking", the ongoing record linking is stopped at
the current position. If DIN3 returns, the record linking is automatically continued from
this position.

With removal of DIN9 "Mode shift", the ongoing record linking is ended. The ongoing
position record is still run to the end.

With removal of DIN13 "Stop", record linking is interrupted. Record linking must then
be started again.