background image

6. Electrical installation

106

Festo P.BE-CMMD-AS-HW-EN 1002NH

Pin

Designation

Value

Mode = 0 – Positioning

22

DIN6

Limit switch 0

23

DIN8

Start for the positioning process (high active)

24

DOUT0

24 V100 mA

Ready for operation output (high active)

25

DOUT2

24 V100 mA

Output freely programmable – default: Start ack (low active)

Table 6.2 Pin allocation: I/O interface [X1] mode 0

Pin

Designation

Value

Mode = 1 – Jog mode

1

AGND

0 V

Screen for analogue signals

2

DIN12

24 V

Mode switch "1" = Jog mode

3

DIN10

Jog + (high active)

4

+VREF

+10 V ±4 %

Reference output for setpoint potentiometer

5

Free

6

GND24

Reference potential for digital inputs and outputs

7

DIN1

Record selection 1 (high active)

8

DIN3

Record selection 3 (high active)

9

DIN5

Controller enable/EN (high active)
(Taught positions are saved with negative edge)

10

DIN7

Limit switch 1

11

DIN9

SAMP

Digital I/O control interface:
Mode selection "0" = jog mode (high active)
Fieldbus control interface:
Sample input (high-speed input)

12

DOUT1

24 V100 mA

Output freely programmable – default motion complete (high active)

13

DOUT3

24 V100 mA

Output freely programmable – default error (low active)

14

AGND

0 V

Reference potential for the analogue signals

15

DIN13

Stop input (low active)

16

DIN11

Jog – (high active)

17

AMON0

0 ... 10 V

Analogue monitor output 0

18

+ 24 V

24 V100 mA

24 VDC feed-in carried out

19

DIN0

Record selection 0 (high active)

20

DIN2

Record selection 2 (high active)

21

DIN4

Output stage enable (high active)

22

DIN6

Limit switch 0

23

DIN8

Teach (high active)

24

DOUT0

24 V100 mA

Ready for operation output (high active)

25

DOUT2

24 V100 mA

Teach ack

Table 6.3 Pin allocation: I/O interface [X1] mode 1

Pin

Designation

Value

Mode = 2 – Route program

1

AGND

0 V

Screen for analogue signals

2

DIN12

Mode switch "0" = route program

3

DIN10

Next 1

4

+VREF

+10 V ±4 %

Reference output for setpoint potentiometer

5

Free

6

GND24

Reference potential for digital inputs and outputs

7

DIN1

Record selection 1 (high active)

8

DIN3

Stop route program

Advertising