8. Service functions and error messages

124

Festo P.BE-CMMD-AS-HW-EN 1002NH

Error message

Meaning of error
message

Measures

Error reaction

Main
index

Sub-
index

45

0

Driver supply failure

Driver supply active despite safe halt

PS off

1

Driver supply failure

Driver supply back on despite secure halt

PS off

2

Driver supply failure

Driver supply does not go on although safe
halt is no longer active

PS off

3

Plausibility error DIN 4

Output stage enable error

PS off

64

0

DeviceNet initialisation
error

PS off

1)

1

DeviceNet assembly error

PS off

1)

2

DeviceNet communication
error

Common fault

PS off

1)

3

DeviceNet communication
error

Common fault

PS off

1)

4

DeviceNet communication
error

Common fault

PS off

1)

5

DeviceNet communication
error

Common fault

PS off

1)

6

DeviceNet communication
error

Common fault

PS off

1)

65

0

DeviceNet assembly error

PS off

1)

1

DeviceNet communication
error

Common fault

PS off

1)

70

2

General arithmetic error

The FHPP factor group cannot be calculated
correctly.

PS off

3

Operating mode error

Change in operating mode when output
stage is released.

PS off

1)

76



0

Error in SSIO
communication (master –
slave)

Common error:
1. Checksum error in transmission of the
SSIO protocol
2. Time out during transmission

PS off

1

Error in SSIO
communication (partner)

SSIO partner has error 760

PS off

79

0

RS232 communication
error

Common fault

PS off

1)

1)
PS off
QStop
Warn
Ignore

Changeable with FCT
Switch off power section
Fast stop
Warning
Ignore

Table 8.2 Error messages

Error messages can be acknowledged by:

- the parametrisation interface
- via the fieldbus (control word)
- a falling edge at DIN5 (controller enable).


Note

Safety devices must be regularly checked according to the
characteristics of the system.