3. Product description

Festo P.BE-CMMD-AS-HW-EN 1002NH

35

Limit switch

The limit switches serve to limit the range of motion for safety reasons. During homing,
one of the two limit switches can serve as reference points for positioning control.

Sample input

If a fieldbus is used for activation, a high-speed sampling input is available for time-critical
tasks for various applications (position sensing, special applications, ...).

Analogue input

The CMMD-AS motor controller has an analogue input for input levels ranging from
+10 VDC to –10 VDC. The input is a differential input (12 bit), ensuring a high degree of
protection against interference. The analogue signals are quantified and digitalised by
the analogue-digital converter at a resolution of 12 bits. These analogue signals serve to
specify setpoints (speed or torque) for the control.

Basic functions

The existing digital inputs are already allocated to the basic functions in standard
applications. The analogue input AIN0 is also available as a digital input for use of further
functions, such as the jog function, route program and synchronisation.
Mode switching allows you to switch between the following default settings:

Mode

Function

Mode 0

Positioning

Mode 1

Jog function

Mode 2

Travel program

Mode 3

Synchronisation

Table 3.3 Mode switching

3.5.5

RS232 interface (diagnosis/ parametrisation interface)

The RS232 interface is intended as a configuration interface.

Parameter

Signal level

In accordance with RS232 specification or RS485 specification

Baud rate

9600 baud to 115 kBaud

ESD protection

ESD-protected (16 kV) driver

Connection

Null modem standard [X5]

Connector socket

over [X5] / D-Sub 9 pin / pin

Table 3.4 Parameters of the RS232 interface