3. Product description

Festo P.BE-CMMD-AS-HW-EN 1002NH

49

3.7

Function overview

3.7.1

Operating modes

- Setpoint specification via increment generator signals, suitable for frequencies

up to 150 kHz

- Analogue speed specification with 12-bit resolution
- Reference point
- Simple connection via digital inputs and outputs to a higher-order controller,

e.g. a PLC.

- Jolt-limited or time-optimised positioning absolutely or relative to a reference

point via the integrated trajectory generator.

- Position specification via the integrated fieldbus CANopen with automatic

interpolation between the setpoints

Operating mode

Function

(Setpoint value) interface

Setpoint specification via

Regulating torque

Analogue setpoint

[X1]

Fieldbus

Direct mode

Speed control

Analogue

[X1]

CW/CCW signals

[X1] (24 V / mode 3)
[X10] (5 V)

CLK/DIR
pulse/direction signals

[X1] (24 V / mode 3)
[X10] (5 V)

Fieldbus

Direct mode

Master/Slave

A/B signals +
I/O (start synchronization)

[X10]
[X1] (mode 3)

Position control
(CAN DS402)

Fieldbus

Interpolated Position Mode

Fieldbus

Direct mode

Positioning controller –

I/O

Record selection

Fieldbus

Direct mode

Fieldbus

Record selection

Homing

I/O

Record selection

Fieldbus

Direct mode

Fieldbus

Record selection

Jog mode

I/O

Fieldbus

Direct mode

Teach-in function

via I/O

Table 3.14 Operating modes