Motor connection [x6.1/2, Power supply [x9, 6 motor connection [x6.1/2 – Festo Контроллер двигателя CMMD-AS User Manual

Page 110: 7 power supply [x9

Advertising
background image

6. Electrical installation

110

Festo P.BE-CMMD-AS-HW-EN 1002NH

6.4.6

Motor connection [X6.1/2]:

Version on controller

Counterplug

Plugged/optional plug set

Material number

Combicon, 8-pin socket

MSTB 2.5/8-ST-5.08 BK

Blanking plug kit

547 452

Table 6.10 Plug version: Motor connection [X6]

Pin no.

Designation

Value

Specification

1

BR–

0 V brake

Motor holding brake,
signal level dependent on switch condition

2

BR+

24 V brake

3

–MTdig

0 V Temp.

Motor temperature sensor, NC, NO, PTC, KTY.

4

+MTdig

+3.3 V / 5 mA

5

PE

PE motor connection

PE connection in the motor cable

6

W

See technical
specifications

Connection of the 3 motor phases *

7

V

8

U

*The motor cable screen is fitted to the controller housing (The fastening flange is specially shaped for
this.)

Table 6.11 Pin allocation: Motor connection [X6]

6.4.7

Power supply [X9]

Version on controller

Counterplug

Plugged/optional plug set

Material number

Combicon, 7-pin socket

MSTB 2.5/7-G-ST-5.08 BK

Plugged

547 452

Table 6.12 Plug version: Power supply [X9]

Pin no.

Designation

Value

Specification

1

L1

Single-phase, 95 ... 255 V
AC, suitable for USA/EU
mains voltage

Mains voltage connection for ZK

2

N

3

ZK +

320 V DC

ZK+ connection for external brake resistance,
not short-circuit-proof against L1, N and PE!

4

BR-CH

0 V / 400 V,
max. 4 A
R

BR

> 100

Connection for external brake resistance against ZK+

5

PE

PE

PE connection of the mains power supply

6

24V

+24 V / 1 A

Supply for the control portion with DCDC converter,
DOUT0 to DOUT3 and holding brake, max. 1A

7

0V

GND

Common reference potential for the logic power
supply and the control section

Table 6.13 Pin allocation: Power supply [X9]