Festo Контроллер двигателя CMMD-AS User Manual

Page 61

Advertising
background image

3. Product description

Festo P.BE-CMMD-AS-HW-EN 1002NH

61

Controller

released

Drive is moving

0

1

0

1

0

1

0

1

0

Holding brake

current-carrying

1

DOUT0: READY

Output stage

release

1

Motor controlled

0

ty

t1

t1

= 1.6 ms

tx

= x ms (dependent on brake ramps)

Fig. 3.8 Behaviour when switching off end-stage enable

Note

The holding brake of the EMMS-AS-…- is not suitable for braking
the motor.