3. Installation

3.1.

Installation

You can integrate the 2130IB bus interface module into the controllers
of the 4900, 8600, 9200 series.
It is also possible to use it together with the Lenze automation module
for positioning (2211PP) and winding applications (2211WP).
If you purchase the bus interface module separately, you will need an
installation kit.

Name

Service no.

Explanation

Installation kit 8600-
4900/2130IB

33.4900_N.V013

Installation kit for the 8600 and 4900
series

Installation kit 9200/2130IB

33.9200_N.V008

Installation kit for the 9200 series

Assembly instructions are included in the installation kits.
Further installation kits for the controllers of the 9200 series can be
obtained on request.

3.2.

Wiring

3.2.1.

2130IB.V001 (RS485)

Communication media

RS485 (2-wire)

Network topology

Line

Number of controllers

31 without repeater. With repeater
max.126.

Maximum cable length

1200 m (depending on the desired baud
rate and cable type. See following cable
specification)

Maximum baud rate

1500 kBaud

X12 Socket 9-pole SubD (RS485)

View

Pin no.

Signal name

Name

1

2

3

4

5

6

7

9

8

1
2
3
4
5
6
7
8
9

PE

RxD / TxD-P
RTS
M5V2
P5V2

RxD / TxD-N

Protective earth

Data line B
Request To Send
Data reference potential
Supply plus

Data line A