Lenze 2130IB User Manual

Page 55

Advertising
background image

53

Meaning

R/W

Read-Write authorization via LECOM2 (PROFIBUS)

Ra

Read-only always permitted

Ra/W

Reading is always permitted; writing is restricted (e.g. depending on
L-C001 ("operating mode") or operating state (change only after
controller inhibit).

PCD

Mapping to PROFIBUS process data (Index 6010

hex

, 6011

hex

)

PI

Process input data (from controller to host)

PO

Process output data (from host to controller)

POI

Process input and output data (see PI and PO)

Process data mapping is not possible

SP

Non-volatile parameter saving

y

Yes

− Parameter will be saved

n

No

− Parameter will not be saved

Parameter depends on the process and is not saved.

Data str.

Data structure

S

Simple variable (simple parameter). The parameter has only one
value. Addressing is only possible with subindex 0.

A

Array variable (field parameter). The parameter has several values
which are of the same data type. Direct addressing of single elements
is possible with the subindex.
With subindex = 0 the complete parameter content is addressed.

R

Record variable (combined variable). The parameter has several
values, which may have different data types. Direct addressing of the
single elements is possible with the subindex.
With subindex = 0, the complete parameter content is addressed.

Data type

Data type

BOL

Boolean

(FALSE = 00

hex

;TRUE = FF

hex

)

I8

Integer8

( -128 <= x <= 127 )

I16

Integer16

( -32768 <= x <= 32767 )

I32

Integer32

(-2147483648 <= x <= 2147483647)

U8

Unsigned8

( 0 <= x <= 255 )

U16

Unsigned16 ( 0 <= x <= 65535 )

U32

Unsigned32 ( 0 <= x <= 4294967295)

OS

Unsigned16. 8 bit/byte binary coded

VS

Visible-String. Text, coded to ISO 646

PDS

Process data description structure (Index 20

hex

). For the description of

the structure see chapter "process data configuration" (page 67)

RS

Ramp structure (Index 21

hex

)

Subindex 1: U32

Numerator delta speed in min

-1

Subindex 2: U16

Denominator delta time in seconds

Data num.

Number of parameter elements

Data leng.

Total length of the parameter in byte.

Advertising