Process output data (6011 – Lenze 2130IB User Manual

Page 73

Advertising
background image

71

4.6.2.

Process output data (6011

hex

)

Data format:

Unsigned16 with 4 elements

Process data are data memories where several individual parameters
are combined to form a new parameter, the process data. These
process data are exchanged as fast as possible and cyclically between
the controller and the master. Process output data are output data of
the master and thus input data of the controller. The process data
have a fixed length of 4 byte and a summary of parameters is
described in the chapter "process data configuration" (page 67).

Factory setting of the process output dataFactory setting of
process output data:

Byte no.

Auto-
mation
module

Meaning

Index

1

Word1/High-Byte
Bit 8 - 15

POW1

2

Word1/Low-Byte
Bit 0 - 7

No
Yes

DRIVECOM control word
Automation control word

6040

hex

58C5

hex

3

Word2/High-Byte
Bit 8 - 15

PIW 2

4

Word2/Low-Byte
Bit 0 - 7

No
Yes

DRIVECOM nominal speed value
Automation FDI1

6042

hex

5A9B

hex

4.7. Speed/Velocity channel

4.7.1.

Pole number (604D

hex

)

The parameter "pole number" exists only for frequency inverters. It
indicates the pole number of asynchronous motors and is used to
convert frequency values to speed values and vice versa. Only even
numbers are possible.
This is shown on Lenze parameter L-C092.

Index

Sub-
index

Data
str.

Data
type

Range/Initialization

604D

hex

0

S

U8

2 to 254
L-C092