L
54
4.2. Controller states
4.2.1.
Status diagram of standard control
For standard control you enter the control information via terminal,
keypad or LECOM1 (standard interface LECOM-A/B). The setting is
done using Lenze parameter L-C001 (page 24).
The information about the momentary controller state (blocks) are
contained in the profile parameter "status word" or "automation status
word". Commands in the profile parameter "control word" are switched
off and cannot cause a change of the controller state. The commands to
change the controller states are entered using the corresponding control
inputs (terminal / keypad / LECOM-A/B). These commands are marked
with **.
Status diagram standard control
NOT READY TO SWITCH ON
Status word xxxx xxxx x0xx 0000
automatic when
initializing is completed
READY TO SWITCH ON
Status word xxxx xxxx x01x 0001
SWITCHED ON
Status word xxxx xxxx x01x 0011
automatic
RFR**
RSP**
OPERATION ENABLED
Status word xxxx xxxx x01x 0111
Malfunction
Status word xxxx xxxx x0xx 1000
TRIP-Reset**
Switch on devices
TRIP
(fault)
QSP**
** means command.