Process output data enable (6002 – Lenze 2130IB User Manual

Page 72

Advertising
background image

L

70

4.5.3.

Process output data enable (6002

hex

)

Inhibiting and enabling of process output data (output data of the
master). More detailed information about the use of the parameter can
be obtained from the chapter "process data configuration" (page 67).

Index

Sub-
index

Data
str.

Data.
type

Range / Initialization

6002

hex

0

S

OS-1 00

hex

Inhibit output data

FF

hex

Enable output data.

4.6. Process data

4.6.1.

Process input data (6010

hex

)

Data format:

Unsigned16 with 4 elements

Process data are data memories where several individual parameters
are combined to form a new parameter, the process data. These
process data are exchanged as fast as possible and cyclically between
the controller and the master. Process input data are input data of the
master and thus output data of the controller. The process data have a
fixed length of 4 byte and a summary of parameters is described in the
chapter "process data configuration" (page 67).
Factory setting of the process input data:
Byte no.

Auto-
mation
module

Meaning

Index

1

Word1/High-Byte
Bit 8 - 15

PIW1

2

Word1/Low-Byte
Bit 0 - 7

No
Yes

DRIVECOM status word
Automation status word

6041

hex

58C4

hex

3

Word2/High-Byte
Bit 8 - 15

PIW 2

4

Word2/Low-Byte
Bit 0 - 7

No
Yes

DRIVECOM actual speed
Automation FDO1

6044

hex

5A98

hex

Advertising