1.3. Commissioning sequence

The initial commissioning of the 2130IB bus interface module together
with a controller and possibly an automation module is divided into the
following phases:

Base setting of the controller
In this phase the controller receives information about additional modules
and the source of the control information.
This setting is possible using the keypad at the controller of the LEMOC2
PC program.

PROFIBUS bus parameters
It is not necessary to set PROFIBUS bus parameters for the operation
with PROFIBUS-DP. With the factory setting, the 2130IB module is set
automatically to the baud rate of the master.
In addition, you can enter the PROFIBUS address via PROFIBUS.
Modified bus parameters are automatically saved permanently.

For PROFIBUS-FMS or PROFIBUS mixed operation, a local setting of
the baud rate and the address is necessary. These parameters can be
set using the LEMOC PC program, which is included on the attached
diskette. For this, make a LECOM-A/B connection for commissioning.

PROFIBUS drive control
The drive system is controlled via PROFIBUS. Control information is
transmitted to the controller, and the controller returns feedback
information to the master.