Setting using the LEMOC2 PC program
1.

Change to your LEMOC2 directory (...\LM2\BIN) and
start LEMOC2 by entering LM2.

2.

Load the file "2130_xxx.PDB"

(x = serial number)

in the menu "file / controller description".

3.

Load a parameter which contains the corresponding factory setting
in the menu "file / load parameter set".

The following parameter sets are available:
2130_FMS.VAR

Parameter set for PROFIBUS-FMS or
mixed operation

2130_DP.VAR

Parameter set for PROFIBUS-DP

4.

Connect your PC to the controller and switch LEMOC2 on-line.
For this, use the option "setting / general settings".

5.

Inhibit controller (press STP key or F9 key or use controller inhibit
terminal 28).

6.

The 2130IB module can now be activated in the menu
"main menu / drive system"
Set parameter L-C370 (C0370-000) to -1- and transmit the
value to the controller.

6a.

Only required for automation module:

Set parameter L-C1120 (C1120-000) to -3- and
transmit the value to the controller.

Note:

When L-C370 or L-C1120 are modified, the internal interfaces between
the modules are re-initialized. This may result in a delay or refusal of
other services for the time of initialization (max. 30 s). If this is the case,
repeat the service.

7.

Set the operating mode with parameter L-C001
(C0001-000), according to the keypad setting, item 5, and transmit
the value to the controller.

8.

Save the setting in the controller by setting parameter L-C003 to
-1- and by transmitting the value to the controller.

8a.

Only required for automation module:

Save the setting in the controller by setting parameter L-C1003 to
-1- and transmitting the value to the controller.

9.

Enable the controller (press SH + STP keys or F8 key, depending
on item 5). It may be necessary to undo other controller inhibit
sources (terminal 28, TRIP, L-C40).

10. Further information about LEMOC2 and possible error messages

can be obtained from the LEMOC2 help function
(key 1 or "help" menu).

Note:

If you activate the function "Load factory setting" at the controller, the
settings described under 1 to 7 are deleted.