Quick stop time (6051 – Lenze 2130IB User Manual

Page 67

Advertising
background image

65

4.3.3.

Quick stop time (6051

hex

)

The parameter "quick stop time" corresponds to the relative speed
ramp of the deceleration for the control commands "quick stop",
"disable ramp function generator" or the QSP terminal function.
The deceleration time refers to the parameter "speed reference"
(index = 604E

hex

).

Slope

Index

E

Index

hex

hex

=

=

=

'

'

(

)

'

(

)

Speed reference

Quick stop time'

604

6051

The parameter is mapped to the ramp-min function via the Lenze
quick stop ramp (L-C105). If the quick stop time = 0, the ramp is
switched off.

Index

Sub-
index

Data
str.

Data
type

Range/Initialization

6051

hex

0

S

U32

0 to 495000 (max L-C105 / 2)
L-C105 / 2
Delta time in milliseconds