Lenze 2130IB User Manual

Page 22

Advertising
background image

L

20

3.2.3.

Additional procedure for FMS / mixed operation

When using the FMS / mixed operation, some parameters must be set
for the controller and the field bus module, which is only possible by
means of the LECOM1 interface.
For the parameter setting of the controllers using the LEMOC2
program, connect the PC (RS232) and the controller (LECOM1; X6) by
means of a PC system cable.

Name

Part no.

Explanation

PC system cable 5 m

338 094

System cable 5m between PC (9-pole
socket) and controller

PC system cable 10 m

338 095

System cable 10m between PC (9-pole
socket) and controller

Cable type
Cable resistance
Capacitance per unit length
Length

LIYCY 4 x 0.25mm

screened
< 100

Ω/km

< 140nF/km
≤ 15m

Wiring of the system cable

Controller
9-pole SubD socket
Pin no.

PC or similar
9-pole socket
Pin no.

PC or similar
25-pole socket
Pin no.

2 (RxD)

3 (TxD)

2 (TxD)

3 (TxD)

2 (RxD)

3 (RxD)

5 (GND)

5 (GND)

7 (GND)

Only use metallized SubD housings. Connect the screen to the
housings at both ends.