Lenze 2130IB User Manual

Page 82

Advertising
background image

L

80

Structure of the parameter "automation control word":

Bit

Name

Meaning

0

Switch on

Controller states
0 = command 2,6,8 (controller inhibit)
1 = command 3 (not controller inhibit)

1

Disable voltage

Controller states
0 = command 7,9,10,12 (controller inhibit)
1 = not command disable voltage

2

Quick stop

Controller states
0 = command 7,10,11 (quick-Stop)
1 = not command quick stop

3

Operation enabled

Controller states
0 = command 5 (controller inhibit)
1 = command 4 (not controller inhibit)

4

OM-Contr4
2211: PRG-START
2212: not used

Operating mode control function 4 depends on the automation
software package.
0 = inactive
1 = active

5

OM-Contr5
2211: PRG-RESET
2212: not used

Operating mode control function 5 depends on the automation
software package.
0 = inactive
1 = active

6

OM-Contr6
2211: PRG-STOP
2212: not used

Operating mode control function 6 depends on the automation
software package.
0 = inactive
1 = active

7

Malfunction reset

Reset of a fault (TRIP). The bit must be changed from 0 to 1.

8

OM-Contr8
2211: not used
2212: not used

Operating mode control function 8 depends on the automation
software package.
0 = inactive
1 = active

9

OM-Contr9
2211: not used
2212: not used

Operating mode control function 9 depends on the automation
software package.
0 = inactive
1 = active

10

OM-Contr10
2211: not used
2212: not used

Operating mode control function 10 depends on the automation
software package.
0 = inactive
1 = active

11

free 1

Mapping to the 28th freely assignable input (L-1381)
0 = do not activate function
1 = activate function

12

free 2

Mapping to the 29th freely assignable input (L-1381)
0 = do not activate function
1 = activate function

13

free 3

Mapping to the 30th freely assignable input (L-1381)
0 = do not activate function
1 = activate function

14

free 4

Mapping to the 31st freely assignable input (L-1381)
0 = do not activate function
1 = activate function

15

free 5

Mapping to the 32nd freely assignable input (L-1381)
0 = do not activate function
1 = activate function

The individual bit-control commands of the control word are not
independent of the other bit positions. The following list shows which bits
you have to assign in which way in order to activate the desired
command.