5.3. AIF process data base controller

At the moment, the following Lenze parameters can be mapped to the
PROFIBUS process channel:

Function

Data
type

PCD

4900 series

(L-C, index)

8600 series

(L-C, index)

9200 series

CP-n

set

I16

POI

±16384 = ±100%

Reference: n

max

(380;5E83)

±16384 = ±100%

Reference: n

max

(380;5E83)

±26884 = ±100%

Reference: 8000

rpm

(380;5E83)

CP-n

set2

I16

PI

±16384 = ±100%

Reference: n

max

(381;5E82)

±16384 = ±100%

Reference: n

max

(381;5E82)

±26884 = ±100%

Reference: 8000

rpm

(381;5E82)

CP-n

actual

I16

PI

16384 = ±100%

Reference: n

max

(382;5E81)

±16384 = ±100%

Reference: n

max

(382;5E81)

±26884 = ±100%

Reference: 8000

rpm

(382;5E81)

CP-M

set

116

PI

16384 = ±100%

Reference: M

max

Function L-C056

(388;5E7B)

---

±32767 = ±100%

Function: L-C056

(387;5E7C)

CP-M

limit

116

PO

16384 = ±100%

Reference: M

max

Function L-C047

(388;5E7C)

---

±32767 = ±100%

Function: L-C047

(388;5E7B)

CP-actual
angle

U16

PI

0 .. 65535

360° = 16384

(391;5E78)

---

0 .. 65535

360° = 16384

391;5E78)

CP-field
current set-
value

I16

POI

16384 = ±100%

Reference: L-C083

(392;5E77)

---

---

CP-additional
set-value

I16

PI

16384 = ±100%

Function L-C049

(393;5E76)

---

---

CP-FDI1

OS2

POI

Bit 0 ... 7

Terminal E1 ... E8

(136,5F77)

Bit 0 ... 7

Terminal E1 ... E8

(136,5F77)

---

CP-FDO1

OS2

PI

Bit 0 ... 4

Terminal A1 ... A5

(151,5F68)

Bit 0 ... 4

Terminal A1 ... A5

(151,5F68)

---

For explanations about the columns "Data type" and PCD" see chapter
"code table DRIVECOM" (page 52).
Further information can be obtained from the operating instructions of the
base controllers.