Speed reference variable (6043, Actual speed (6044, Nominal percentage (6052 – Lenze 2130IB User Manual

Page 75: Percentage reference variable (6053

Advertising
background image

73

4.7.5.

Speed reference variable (6043

hex

)

The parameter "speed reference variable" corresponds to the
output of the ramp function generator (set-value integrator) in rpm.
The reference variable is multiplied by the inverse of the face value
factor and is mapped to L-C381.

Index

Sub-
index

Data
str.

Data
type

Range/Initialization

6043

hex

0

S

I16

-32768 to 32767
L-C381

4.7.6.

Actual speed (6044

hex

)

The parameter "actual speed" corresponds to the actual speed in
rpm. The actual value is multiplied by the inverse of the face value
factors and is mapped to L-C382.

Index

Sub-
index

Data
str.

Data
type

Range/Initialization

6044

hex

0

S

I16

-32768 to 32767
L-C382
Actual speed in rpm

4.7.7.

Nominal percentage (6052

hex

)

The parameter "nominal percentage" corresponds to the nominal
speed in per cent. This parameter is scaled to the speed reference
(100% = 16383). The set-value is multiplied by the face value factor
and is mapped to L-C380. Changing the "nominal percentage" also
changes the parameter "nominal speed". When reading, the
nominal speed is returned, limited to 200%.

Index

Sub-
index

Data
str.

Data
type

Range/Initialization

6052

hex

0

S

I16

-32768 to 32767
L-C380
Nominal speed in per cent (100% = 16383)

4.7.8.

Percentage reference variable (6053

hex

)

The parameter "percentage reference variable" corresponds to the
speed reference variable (see speed reference variable) in per
cent. It is scaled to the speed reference (100% = 16383). The
reference is multiplied by the inverse of the face value factor and is
mapped to L-C381.

Index

Sub-
index

Data
str.

Data
type

Range/Initialization

6053

hex

0

S

I16

-32768 to 32767
L-C381
Speed reference variable in per cent
(100% = 16383)