Process data configuration – Lenze 2130IB User Manual

Page 69

Advertising
background image

67

4.5. Process data configuration

The process data configuration is used to combine different parameters
to form a new parameter, in order to transmit this parameter as fast and
cyclically as possible. This is the case, for example, for the parameters
"speed set-value" (index = 6042) and "control word" (index = 6040

hex

),

which are combined to form process output data (output data of the
master).

The configuration is done using the parameter "process input data
description" (index = 6000

hex

) and "process output data description

(index = 6001

hex

). The data structure (process data description structure;

index = 20

hex

) of these parameters is shown in the following.

Process data description structure

Sub-
index

Data
type

Meaning
(general)

(Byte PCD)

(Word PCD)

(Double word
PCD)

1

U8

process data length
value fixed to 4

2

U16

index for

1st PCD byte

1st PCDword

1st PCD Dword

3

U8

subindex for

1st PCD byte

1st PCD word

1st PCD Dword

4

U16

index for

2nd PCD byte

0 = not used

0 = not used

5

U8

subindex for

2nd PCD byte

0 = not used

0 = not used

6

U16

index for

3rd PCD byte

2nd PCD word

0 = not used

7

U8

subindex for

3rd PCD byte

2nd PCD word

0 = not used

8

U16

index for

4th PCD byte

0 = not used

0 = not used

9

U8

subindex for

4th PCD byte

0 = not used

0 = not used

The table describes the data structure of the parameter and the meaning
of the entries for byte, word, or double word parameters. In the first
subindex, the length of the process data is entered. The next part is a
description of the parameter which is assigned to each byte of the
process data. The description is the address of the parameter, which
consists of index and subindex.