18

How to wire the module

• Only use cables according to the following cable specification.
• Observe the following illustrations concerning the bus connector.
• Make the connection to the controllers using the bus connector.

The bus system is not interrupted if you disconnect the plug from
the controller.

• Connect a terminating resistor at the physical bus ends . This

resistor is integrated in the bus connection plug. You can activate it
by using a switch.

• If the 2130IB bus interface module is not supplied with power any

more, the bus system continues to operate. The connected
controller, however, cannot be called by the host.

• If you want to disconnect individual bus participants, make sure that

the terminating resistors at the physical cable ends remain active.

• Further notes and wiring instructions can be obtained from the

documentation of the control manufacturer.

Connection of the bus cable in the bus connector

ON

A B A B

4

5

V

V

1 = 9-pole SubD connector
2 = Guides for the bus cable
3 = Housing screw
4 = Terminating resistor (not connected))
5 = Cable screen; must lay bare
on the metal guide

V

1

2

3

V

V

approx. 6 mm

approx. 11 mm

approx. 11 mm

cable screen

bus cable

V

V