Chapter 8

Slave Modes for Multi-axis Cascaded Systems

HOST GROUPS

Do

or C

on

tr

ol

57

Door Out Type
Door Output Type
Defines the lock and unlock state for door control output (DC_Out).
When Door Out Type equals power to release, DC_Out is OFF in the lock state and ON in
the unlock state.
When Door Out Type equals power to lock, DC_Out is ON in the lock state and OFF in the
unlock state.
The first and middle units of a multi-axis system must be configured as cascading (2).

Default:
Options:

0 = “Pwr to Rel”
0 = “Pwr to Rel”
1 = “Pwr to Lock”
2 = “2 Ch Sourcing”

RW 8-bit

Integer

58

DM Input
Door Monitor Input
Configuration for the Door Monitor input (DM_In).
“2 OSSD 3s” (5) – Dual-channel SS equivalent 3 s

Options:

5 = “2 OSSD 3s”

RW 8-bit

Integer

Fi

le

Grou

p

No.

Display Name
Full Name
Description

Values