Safe Limited Speed (SLS) Modes

Behavior While SLS Monitoring is Inactive

If Safe Limited Speed monitoring is inactive, the DM_In input must be ON
(door closed) or a Door Monitoring fault occurs and the safety option initiates
the configured P45 [Safe Stop Type]. The ESM_In input can be ON or OFF.

Behavior During SLS Monitoring Delay

The status of the ESM_In input does not affect the operation of the system
during a P53 [LimSpd Mon Delay]. However, the DM_In input must be ON
(door closed) during the delay or a Door Monitoring fault occurs and the safety
option initiates the configured P45 [Safe Stop Type].