Safety concept, Introduction, Safety certification – Rockwell Automation 21G PowerFlex 750-Series AC Drives Reference Manual User Manual

Page 15: Chapter 1, Introduction safety certification, Chapter

Advertising
background image

Rockwell Automation Publication 750-RM001F-EN-P - February 2012

15

Chapter

1

Safety Concept

Introduction

This chapter describes the safety performance level concept and how the
PowerFlex 750-Series drives can meet the requirements for SIL CL3, CAT 4, or
PL e applications.

Safety Certification

The PowerFlex 750-Series safety option is certified for use in safety applications
up to and including SIL CL3 according to EN 61800-5-2, EN 61508, and EN
62061, Performance Level PL e and CAT 4 according to ISO 13849-1. Safety
requirements are based on the standards current at the time of certification.

The TÜV Rheinland group has approved the PowerFlex 750-Series safety option
for use in safety-related applications where the de-energized state is considered to
be the safe state. All of the examples related to I/O included in this manual are
based on achieving de-energization as the safe state for typical Machine Safety
and Emergency Shutdown (ESD) systems.

Topic

Page

Safety Certification

15

Functional Proof Tests

18

PFD and PFH Definitions

18

Safe State

19

Safety Reaction Time

20

Considerations for Safety Ratings

20

Contact Information if Safety Option Failure Occurs

22

Advertising