Safe Maximum Speed and Direction Monitoring

Chapter 9

Figure 44 - Positive Safe Direction Monitoring Timing Diagram

P42 [Direction Mon] = 1 “Pos Always”

Figure 45 - Negative Safe Direction Monitoring Timing Diagram

P42 [Direction Mon] = 2 “Neg Always”

If motion is detected in the incorrect direction while Safe Direction Monitoring
is active, a Direction fault occurs. If a Direction fault is detected while the safety
option is monitoring motion, the configured P45 [Safe Stop Type] is initiated
and direction monitoring is not performed during the safe stop. If a Direction
fault is first detected after the initiation of the safe stop, then all outputs go to
their faulted state.

For more information about faults, see

Fault Reactions

on

page 155

.

0

300

Speed

Safe Direction Fault

Time

Safe Direction

0

-300

Speed

Time

Safe Direction

Safe Direction Fault