Rockwell Automation Publication 750-RM001F-EN-P - February 2012

73

Safe Stop and Safe Stop with Door Monitoring Modes

Chapter 6

Safe Stop with Door
Monitoring Parameter List

To configure the safety option for Safe Stop with Door Monitoring, set the DM
Input parameter in addition to the Safe Stop parameters listed on page 69.

Fil

e

Gr

oup

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta

T

yp

e

HO

ST

GR

O

U

PS

Gene

ral

21

Safety Mode
Safety Mode
Defines the primary operating mode of the speed monitoring safety functions.

Setting:

2 = “Safe Stop DM”

RW 8-bit

Integer

Do

or Con

trol

58

DM Input
Door Monitor Input
Configuration for the Door Monitor input (DM_In).
“2NC” (1) – Dual-channel equivalent
“2NC 3s” (2) – Dual-channel equivalent 3 s
“1NC+1NO” (3) – Dual-channel complementary
“1NC+1NO 3s” (4) – Dual-channel complementary 3 s
“2 OSSD 3s” (5) – Dual-channel SS equivalent 3 s
“1NC” (6) – Single channel equivalent

Default:
Options:

0 = “Not used”

(1)

0 = “Not used”
1 = “2NC”
2 = “2NC 3s”
3 = “1NC+1NO”
4 = “1NC+1NO 3s”
5 = “2 OSSD 3s”
6 = “1NC”

RW 8-bit

Integer

(1) You must configure this parameter with a non-zero value in this mode.