Rockwell Automation Publication 750-RM001F-EN-P - February 2012

83

Safe Limited Speed (SLS) Modes

Chapter 7

SLS with Door Monitoring
Wiring Example

This example illustrates wiring for SLS with door monitoring.

Figure 21 - Master, Safe Limited Speed with Door Monitoring (First or Single Unit)

(1) Lock monitoring connections are not required for Safe Limited Speed with Door Monitoring mode operation.

Safe Limited Speed with
Enabling Switch Monitoring
Mode

When properly configured for Safe Limited Speed with Enabling Switch
Monitoring, the safety option performs Safe Limited Speed (SLS) monitoring
functions as described in

Safe Limited Speed (SLS) Mode

on

page 75

in addition

to the Safe Stop functions as described in

Safe Stop Mode

on

page 61

.

In addition, the safety option monitors the Enabling Switch Monitor input
(ESM_In) after the Safe Limited Speed Monitoring Delay [LimSpd Mon Delay]
times out. Once the enabling switch is activated, the ESM_In input must remain
ON while Safe Limited Speed monitoring is active or an ESM Monitoring fault
occurs. An ESM Monitoring fault is a Stop Category fault, which initiates the
configured Safe Stop Type.

GND

S11

S11

S11

S21

S21

S21

TEST_OUT_0

TEST_OUT_1

+24V DC

TB1

TB2

S11

S11

S11

S21

S21

S21

A1

S12

S22

S72

S82

S52

S62

S32

S42

X32

X42

34

44

68

78

51

52

S34

A2

+24V

24V_COM

SS_IN_CHx

ESM_IN_CHx

SLS_IN_CHx

DM_IN_CHx

LM_IN_CHx

SS_OUT_CHx

SLS_OUT_CHx

DC_OUT_CHx

RESET_IN

A1

S12

S22

S72

S82

S52

S62

S32

S42

X32

X42

34

44

68

78

51

52

S34

A2

12 22 34

11 21 33

A1

A2

42

41

52

51

(1)

PowerFlex 750-Series
Safe Speed Monitor
Option Module

SLS

Request

SS

Request

Reset

Safety Stop
to Next Axis
(optional)

Remove (2)
Internal
Jumpers

Power to

Release

TLS3 GD2
440G-T27260
Safety Switch

IMPORTANT

When Safe Limited Speed Monitoring is inactive, the ESM_In input is not
monitored.