Rockwell Automation Publication 750-RM001F-EN-P - February 2012

Chapter 7

Safe Limited Speed (SLS) Modes

SLS with Door Monitoring
and Enabling Switch
Monitoring Wiring Example

This example illustrates wiring for SLS with door monitoring and enabling
switch monitoring.

Figure 24 - Master, Safe Limited Speed with Door Monitoring and Enabling Switch Monitoring
(First or Single Unit)

(1) Lock monitoring connections are not required for Safe Limited Speed with Door Monitoring and Enabling Switch Monitoring mode

operation.

GND

S11

S11

S11

S21

S21

S21

TEST_OUT_0

TEST_OUT_1

+24V DC

TB1

TB2

S11

S11

S11

S21

S21

S21

A1

S12

S22

S72

S82

S52

S62

S32

S42

X32

X42

34

44

68

78

51

52

S34

A2

+24V

24V_COM

SS_IN_CHx

ESM_IN_CHx

SLS_IN_CHx

DM_IN_CHx

LM_IN_CHx

SS_OUT_CHx

SLS_OUT_CHx

DC_OUT_CHx

RESET_IN

A1

S12

S22

S72

S82

S52

S62

S32

S42

X32

X42

34

44

68

78

51

52

S34

A2

12 22 34

11 21 33

A1

A2

42

41

52

51

(1)

1

2

3

4

PowerFlex 750-Series
Safe Speed Monitor
Option Module

SLS

Request

SS

Request

Reset

Safety Stop
to Next Axis
(optional)

Remove (2)
Internal
Jumpers

Power to

Release

440J-N21TNPM

Enabling Switch

TLS3 GD2
440G-T27260
Safety Switch