Application Example 1, Continuous Block

Transfer

Appendix B

BĆ6

113

06

EN

BLOCK XFER WRITE
DATA ADDR:
MODULE ADDR:
BLOCK LENGTH:
FILE:

031
130

00

257 - 356

DN

013

06

113

06

Write Block

Transfer Done Bit

23*

113

06

TON

044

0.1

24

044

15

END 00329

012

00

Output Indicator

25

PR 030

AC 030

WRITE BLOCK TRANSFER

WATCHDOG TIMER AND

INDICATOR

11149

Program Rung Descriptions

rung 1*

Display run. It allows the words pertaining to the module’s
operating characteristics and parameters to be monitored or
changed using the data monitor mode of the industrial
terminal. Because the words are stored in consecutive
files, the position numbers in the data monitor mode will
match the module word numbers.

rungs 2
thru 4*

When pushbutton 111/00 is closed, storage bit 050/00 is

latched. This bit is subsequently used in rung 10 to latch
the load bit and initialize a load/enter sequence. A
load/enter sequence can be initiated at any time. Bit
050/00 is unlatched in rung 14 by the ready bit.

rung 5*

Zeros are loaded into timer/counter address 032 8. The
boundary tells the processor not to look beyond word 0328

for data addresses associated with block transfer

instructions.

rung 6*

The read block transfer instruction reads the next status
block of data set by the module and transfers it to the input