Application Example 1, Continuous Block

Transfer

Appendix B

BĆ14

Bit 10 is controlled in rung 19

Bit 07 = 0

Loop time is reported in the status monitor
byte.

Bit 06

Load bit is controlled by user program.

Bit 05, 04

Verify bits must be 0.

Bit 03 = 0

Enter bit is controlled by user program.

Bit 02 = 0

Set output bit is not used.

Bit 01 = 0

Analog output is set to programmed value if
loss of PV input occurs. Bit 01 is controlled
in rung 17.

Bit 00 = 0

Manual request bit is not used.

Loop 1 Control Word A W18

Bit 17 = 0

Block identifier must be 0.

Bit 16 = 1

Block identifier must be 1.

Bit 15 = 0

The source of the process variable input is
the analog input.

Bit 14 = 0

Square root is not used.

Bit 13 = 0

Error is positive (SP-PV).

Bit 12 = 0

Error limiting is not used.

Bit 11 = 1

Dead band is set to 15 in word W23.

Bit 10 = 1

Integral output is limited to 4000 in word
W26.

Bits 07,06 = 0

Proportional error is not modified.

Bits 05,04 = 0

Integral error is not modified.

Bit 03 = 0

Derivative error is not modified.

Bit 02 = 0

Derivative output is not limited.

Bit 01 = 0

PID output is not held.

Bit 00 = 0

Bias is not held.

Loop 1 Control Word B W19

Bit 17 - 0

Bias is added to the output.

Bit 16 = 1

Output is limited to 4050 in word W29.

Bit 15 = 1

Soft fault response is to continue PID
control.

Bit 14 = 0

Soft fault response is to continue PID
control.

Bit 13 = 0

Soft fault response is to continue PID
control

Bit 12 = 0

Digital filter time is multiplied x1.

Bit 11 = 0

Lead time constant TB is multiplied x1

Bit 10 = 0

Lag time constant TC is multiplied x1