Publication 2092-RM001A-EN-P — March 2005

2-2

Command Reference

Set Parameter (STR)

Set Parameter (CHP)

Command:

STR

Description:

Write parameter value to RAM, and then save data from RAM to
flash memory.

Format:

STX ID # STR PPP V : BSS ETX

Data:

Argument

Description

PPP

Parameter #; (e.g., [Pr-2.03], PPP=203=0x0CB).
Refer to Parameters on page 2-14 for the list of
parameters.
Parameters in Group 7 (manufacturing settings)
cannot be set.

V

Parameter value to save, 4 or 8 bytes signed

Response Format: ACK

Error Response:

If unable to change the variable because drive is enabled, GS is
sent. If value is out of range, RS is returned.

Next Command:

STX ID # STR : BSS ETX

Usage Note:

To determine whether task is complete, send STR without
arguments.

Response Format: If task is not complete: STX ID $ BSY : BSS ETX

or

If task is complete: STX ID $ TOK : BSS ETX

Command:

CHP

Description:

Write parameter value to RAM

Format:

STX ID # CHP PPP V : BSS ETX

Data:

Argument

Description

PPP

Parameter #; In the case of [Pr-2.03],
PPP=203=0x0CB. Refer to Parameters on
page 2-14 for the list of parameters.
Parameters in Group 7 (manufacturing settings)
cannot be set.

V

Parameter value to save, 4 or 8 bytes signed

Response Format: ACK

Error Response:

If unable to change the variable because drive is enabled, GS is
sent. If value is out of range, RS is returned.

Advertising