Publication 2092-RM001A-EN-P — March 2005

2-28

Command Reference

Group 3 Parameters

[Pr – 3.00] Follower

Data Size:

4 digits

Digit 0:

Command Type

Range:

Value Description

0x0

Step/Direction - CW + CCW, positive logic

0x1

Step/Direction - CW + CCW, negative
logic

0x2

Step Up/Step Down - Pulse Line + Sign,
positive logic

0x3

Step Up/Step Down - Pulse Line + Sign,
negative logic

0x4

Auxiliary Encoder - A Phase + B Phase,
positive logic

0x5

Auxiliary Encoder - A Phase + B Phase,
double input multiplication, positive logic

0x6

Auxiliary Encoder - A Phase + B Phase,
quadruple input multiplication, positive logic

For command types 0x4, 0x5, and 0x6:

Motor Counts = Master Lines * MULT * .... (4 * [Pr3.01]) / [Pr3.02]

where MULT is 1, 2, or 4 for command types 0x4, 0x5, and 0x6
respectively.

Default:

0x0

Operating Mode:

Follower

Digit 1:

Controller Output Type

Range:

Value Description

0x0

Line driver output to host controller.

0x1

Open collector output to host controller.

Default:

0x0

Operating Mode:

Follower

Digit 2:

Encoder Output Forward Direction

Range:

Value Description

0x0

During forward rotation, Encoder Output
Phase A have a lead of 90

° over Phase B.

0x1

During forward rotation, Encoder Output
Phase B have a lead of 90

° over Phase A.

Default:

0x0

Operating Mode:

All

Digit 3:

“Clear Pos Error” Input Mode