Pr - 0.01] motor and encoder selection, Pr – 0.01] motor and encoder selection -15 – Rockwell Automation 2092-DAx Ultra1500 Host Commands for Serial Communication Reference Manual User Manual
Page 27
Advertising
![background image](/manuals/580418/27/background.png)
Publication 2092-RM001A-EN-P — March 2005
Command Reference
2-15
[Pr – 0.01] Motor and Encoder Selection
Operating Mode:
All
Data Size:
4 digits
Digit 0:
Automatic motor identification
Ultraware Name:
Auto Motor Iden
Range: Value
Description
0x0
Disable automatic motor identification
0x1
Enable automatic motor identification
Default: 1
Digit 1:
Single turn absolute
Ultraware Name:
Encoder Backup Battery
Range: Value
Description
0x0
Installed
0x1
Not Installed
Default: 0
Digit 2:
Encoder line break detect
Ultraware Name:
Incremental Feedback Loss
Range: Value
Description
0x0
Monitor encoder feedback loss error
checking
0x1
Ignore encoder feedback loss error checking
Default: 0
Digit 3:
Reserved
Default: 0